Iridium Technologies

Live Chat
Automated Entry Systems
Electro-mechanical operators, Automatic Boom Barriers, Sensor doors Sliding and Swing Gate
Board Room Automation
Full range of HD and high resolution business projectors
Specialized A/V switchers, cubbies, popup boxes, media wall plates
Lighting automation and control, Businesss & home Theather System, Conference System
CCTV Surveillance Systems
A complete range of Digital video Recorders in Economy and
Premium range IR cameras, Vandal Cameras, Speed Dome
Cameras, Varifocal cameras Professional IP Cameras, Network video recorders, PoE switches
Electronic Access Control & TA
RFID based Access Controllers (Multi and Single doors) Fingerprint/Facial/Palm Geometry Based Controllers TCP/IP and GPRS based color T/A Devices
Fire Detection Systems
Analogue Addressable Fire Detection Conventional Fire Detection Semi-Addressable Fire Detection
Professional Public Announcement Systems
Background Music Systems | Home Multi-room Systems | TCP/IP based speakers | Pro Audio | Special Application Speakers (Water / Explosion )
Sensors & Alarms
Professional wired, wireless and hybrid burglar alarm systems Passive infrared motion sensors, Glass break and magnetic sensors GSM and PSTN auto voice dialers
Video Entry Systems
Color villa type Video Door Phones DIY Kits Villa Type VDP with memory and DVR function (all in one VDP) Multi apartment VDP systems with intercalling
Fire Fighting
Fire Hydrant System, Sprinkler System, Fire Pumps, Piping, Valves, Accessories, Sinages / Extinguisher...
Home >> Fire Detection

Fire Detection

  • GST Intelligent Single & 2 Loop Fire Alarm Control Panel

    Model:- GST200-2

    Description:- The GST 200-2 single loop and two loop addressable fire detection control panel with upto 242 devices per loop, the system is packed with features that are not usually associated with smaller and medium systems. The GST 200-2 provides a high quality solution at exceptional value. By utilizing advanced GST Protocol, the system is compatible with the complete range of GST intelligent Detectors, Sounders, Call Points, Interfaces, including gas extinguishing controls. Networkable with all GST intelligent fire control panels the system can be expanded up to a maximum of 240 GST panels (over 48,000 devices) The GST 200-2 is manufactured and certified to EN54 parts 2 and 4 and to BS5839 Part 4. By utilizing the GSTDef2.1 programming facilities enables advanced and complex cause and effects to be programmed with ease, including phased and cascade evacuation scenarios. The GST zonal indication and control facility allows the operator to manually intervene, with evacuation and control of each zone, including control of all plant equipment under an alarm condition.

    Features:- Listed to LPCB standard, 2 Loop capacity-477 Addressable Point, 8x18 Graphical LCD Display, 30 Zone indication including manual intervention and control, 3 programmable alarm output, Positive Alarm Signal (PAS) Pre-alarm, Maintenance report of dirty detector, Networkable with all GST Intelligent Fire Alarm panels, Programmable form PC by GSTDef2.1, History log 999-events capacity in non-volatile memory, Test Facility-Silent Mode, Device Start/Stop Mode, Device Enable/Disable, RS485 Repeater Output (Max. 10), Advanced user friendly programming software including ‘Fuzzy Logic’, Optional RS 232 Colour Graphics Software, Printer and Pager Interface, Optional RS485 Network Card, Optional Panel Printer.

  • GST102 2 Zone Conventional Fire Alarm Panel

    Model:- GST102


    Description:- The GST104 conventional fire control panels provide two/four zones of fire detection. All panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839. Each zone can be connected with 15 conventional fire detectors. Microprocessor controlled SMT Electronics The GST104 conventional control panels are multi-wire fire alarm developed from SCM. Those with signal output interface board has a passive normally open alarm output contacts and fault output contact on each zone. They have two external control output points to control some devices such as sounder, sounder strobe or bells.

    Features:- Microprocessor controlled SMT Electronics, Compliant with EN54 part 2&4, & BS5839, Part 4, 1988, Both end of line resistors and active end of line can be used. Programmable sounder circuits and outputs, Zone Isolate control, Fully monitored sounder circuits, Key control evacuate over-ride, Class change terminals for remote control, Up to 15 fire detectors and infinite manuals call points each zone.

  • GST102 2 Zone Conventional Fire Alarm Panel

    Model:- GST102

    Description:- The GST102 conventional fire control panels provide two/four zones of fire detection. All panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839. Each zone can be connected with 15 conventional fire detectors. Microprocessor controlled SMT Electronics The GST102/104 conventional control panels are multi-wire fire alarm developed from SCM. Those with signal output interface board has a passive normally open alarm output contacts and fault output contact on each zone. They have two external control output points to control some devices such as sounder, sounder strobe or bells.

    Features:- Microprocessor controlled SMT Electronics, Compliant with EN54 part 2&4, & BS5839, Part 4, 1988, Both end of line resistors and active end of line can be used. Programmable sounder circuits and outputs, Zone Isolate control, Fully monitored sounder circuits, Key control evacuate over-ride, Class change terminals for remote control, Up to 15 fire detectors and infinite manuals call points each zone.

  • Addressable Fire Alarm Panel

    Model No- CFX Fire Panel

    Features:- 2 X 16 character backlit  LCD display. (4 x 20 character, optional),256 Events logging facility with real time clock and keypad. Central Monitoring with GSM Module (Optional).Lamp test feature.Complete with integral power supply and battery charger for SMF battery. Potential free contacts for both fire and fault.Switches & Matrix Keypad 4x4 to enable on board operation.LCD and LED Indication for open, short circuit, Isolate, Fire in each zone. Maximum nos. of Detectors in each zone is 32.20 Characters Address of individual detector in every zone.

  • THERMAL DETECTOR

    Model no : SYSTEM SENSOR 5351E 

    Features: 

     Low profile design,Low current draw,Backward compatible with Series 100 detector range of bases,Wide operating voltage 8 to 30 ,Bi-colour LED detector status indicator,Programmable sensitivity,Addressable feature,Advanced maintenance features via remote hand-held test unit,Range of detector bases available,LPCB Certificate approved.

  • THERMAL DETECTOR 

    Model No: AGNI AD 318-2L

    Featuers:

    Low profile design,Low current draw,Wide operating voltage 8 to 30V DC,Bi-colour LED detector status indicator,58º C Operating Temperature,R emote alarm test feature,Easy Maint enance,Range of detector base s available,R emote LED Option,Approved to EN54 – 5:2000 Class A1R,LPCB Certificate approved.  

  • MULTI CRITERIA PHOTOELECTRIC SMOKE / THERMAL DETECTOR

    Model No: AGNI AD 338-2HL 

    Features:

    Low profile design,Low current draw,Wide operating voltage 8 to 30V DC,Bi-colour LED detector status indicator,Automatic drift Compensation,R emote alarm test feature,Easy Maintenance,Range of det ector bases available,Remote LED Option,Approved to EN54 – 5:2000 (Amendment 1),En 54 – 5:2000 (Amendment 1) Class A1 R ; C E A 4021,LPCB Certificate approved.  

  • PHOTO ELECTRIC SMOKE DETECTOR

    Model No: AGNI AD 338-2 L

    Features:

     Low profile design, Low current draw, Wide operating voltage 8 to 30V DC, Bi-colour LED detector status indicator,Automatic drift compensation,Remote alarm test feature,Easy Maintenance,Range of det ector bases available,Remote LED Option,Approved to EN 54 – 7:2000 (Amendment 1), ,LPCB Certificate approved 

     

  • MULTI CRITERIA PHOTOELECTRIC SMOKE / THERMAL DETECTOR

    Model:SYSTEM SENSOR 2351 TEM

    Features:

    Low profile design, Low current draw, Operating Voltage 8-30V DC, Typical standby current 65µA @ 24V DC, Bi-colour LED detector status indicator, Addressable features, Programmable sensitivity.LPCB Certificate approved.

  • PHOTO ELECTRIC SMOKE DETECTOR

    Model: SYSTEM SENSOR 2351 E

    Features:

    Low profile design, Low current draw, Operating Voltage 8-30V DC, Typical standby current 50µA @ 24V DC, Bi-colour LED detector status indicator, Addressable features, Programmable sensitivity.LPCB Certificate approved.